7 DISPLAY

7.2.3.5.5 In/Out Monitor (5) "6.I/O OTHERS"

Operating Procedure
Switch (1)
Step 1
Display the "ANALYZER MENU" screen.
Step 2
Press switch (1) 5 times to check that "6. I/O OTH-
ERS" is selected, and press (enter) switch (4) to dis-
play "I/O OTHERS 1/2" screen.
NOTICE:
▪ You cannot move directly from "I/O OTHERS"
Switch (4)
screen to the screen of the other items. Re-
turn to "ANALYZER MENU" screen once, then
move to screen of each item.

▪ "I/O OTHERS 1/2"

HR: Hour meter
Displays hour meter value.
BATT: Battery voltage (V)
Displays battery voltage.
Standard: 8.0 to 16.0V
THO: Torque converter oil temperature sensor voltage (V),
and oil temperature (°C)
Displays input voltage from the torque converter oil temper-
ature sensor to the controller, and oil temperature.
Switch (4): To "I/O OTHERS 2/2" screen

▪ "I/O OTHERS 2/2"

IGSW: Key switch
Displays key switch ON/OFF.
IGSW: 1 = ON
IGSW: 0 = OFF
MAT: Matching connector
Displays states of matching connector.
STD lever vehicle:
MAT: 0 = OFF (State of matching connector separation)
MAT: 1 = ON (State of matching connector connection)
Mini lever/Joystick vehicle:
MAT: - = Always
MTC: (Unused)
Switch (4): Returning to "ANALYZER MENU" screen
7-109