SAMPLE MEMORY CELL SETTINGS

Note:
When dispensing fluids that change viscosity, it is generally better to set Auto Increment to
Time instead of Count.
Note:
Within the individual memory cells, it is preferable to leave the dispense time the same, and
only change the pressure from cell to cell in order to maintain the same cycle rate.
Note:
It is recommended to use small pressure adjustments or allow some settling time to ensure
consistent deposit amounts.
Cell 0 – Set initial parameters to produce the desired dot size. For example: 20 psi pressure, .150
seconds dispense time, 0 vacuum. Set the trigger value to 900 (15 minutes).
Cell 1 – Increase pressure to 23 psi, keep .150 seconds dispense time, 0 vacuum. Set the trigger
value to 900 (15 minutes).
Cell 2 – Increase pressure to 27 psi, keep .150 seconds dispense time, 0 vacuum. Set the trigger
value to 900 (15 minutes).
Cell 3 – Increase pressure to 32 psi, keep .150 seconds dispense time, 0 vacuum. Decrease the
trigger value to 540 (9 minutes).
Cell 4 – Increase pressure to 37 psi, keep .150 seconds dispense time, 0 vacuum. Set the trigger
value to 540 (9 minutes).
Cell 5 – Increase pressure to 45 psi, keep .150 seconds dispense time, 0 vacuum. Set the trigger
value to 540 (9 minutes).
Cell 6 – Increase pressure to 55 psi, keep .150 seconds dispense time, 0 vacuum. Decrease the
trigger value to 360 (6 minutes).
Cell 7 – Increase pressure to 65 psi, keep .150 seconds dispense time, 0 vacuum. Decrease the
trigger value to 180 (3 minutes).
Cell 8 – (last cell) – Increase pressure to 80 psi, keep .150 dispense time, 0 vacuum. Decrease
the trigger value to 120 (2 minutes).
If the Auto Increment Alarm is enabled in the Alarm Options screen, the Auto Increment alarm will
engage and further dispensing cycles will be stopped. If the Auto Increment Alarm is disabled, the
timer will continue to increment and dispense cycles will still be allowed – however, the memory cell
address will no longer advance, and will remain at the End Address settings.
Note:
Setting the parameters in the cells needs to be done only one time. When the material
reaches the end of its working life, simply replace it with a full syringe and use the same
preset parameters.
Note:
To start over, highlight AI, then press F2 (Reset). If the AI Alarm is used, resetting the alarm
will also reset the AI mode.