2.2.18 Auto Increment Mode Command
This command changes the Auto Increment Mode to either Timer, Counter, or Auto Sequence mode.
This command also updates the lower four digits of the trigger value.
Host Format:
AC--SsDdddd
s: Mode Command. 1 = Timer Mode, 2 = Counter Mode, 4 = Auto Sequence Mode.
dddd: Trigger Value. 0001 - 9999
2.2.19 Set Start & End Address Command
This command downloads the auto increment start and end addresses.
Host Format:
SS--SsssEeee
sss: Start Address 000 - 339
eee: End Address 000 - 339
2.2.20 Set Trigger Value Command
This command downloads the 5-digit trigger value into the current memory location.
Host Format:
EQ--Tttttt
ttttt: Trigger Value. 00001 - 99999
2.2.21 Set the Real Time Clock Command
This command sets the time on the real time clock on the Ultimus V
Host Format:
EB--HhhMmmAMa
hh: Hours. 0-23 for 24 Hour Format, 1-12 for 12 Hour Format
mm: Minutes. 0-59
a: Hour format. 0 = AM, 1 = PM, 2 = 24 Hour Format
2.2.22 Set the Real Time Date Command
This command sets the date on the real time clock on the Ultimus V
Host Format:
EC--MmmDddYyy
mm: Months. 1-12
dd: Days. 1-31
yy: Years. 00-99
2.2.23 Operator Lockout Set Command
This command updates the operator lockout settings. A '1' indicates that a feature is locked out.
A '0' indicates that the feature is not locked out.
Host Format:
EG--PAppppDTtDPpDVvMmDCcDMdAIaARuALbMMePUfVUgLAhCLjCOkAMn
pppp: 4-digit password. This needs to match the password set on the dispenser. The dispenser
will return an error if incorrect.
t: lockout dispense time: '1'=lockout, '0'=enabled (DT)
p: lockout dispense pressure (DP)
v: lockout dispense vacuum (DV)
m: lockout memory cell selection (DM)
c: lockout deposit counter selection (DC)
d: lockout dispense mode change (DM)
a: lockout Auto Increment Mode selection (AI)
u: lockout Auto Increment Reset (AR)
b: lockout Alarms Reset (AL)
e: lockout Main Menu selection (MM)
f: lockout Pressure Unit Menu selection (PU)
g: lockout Vacuum Unit Menu selection (VU)
h: lockout Language Menu selection (LA)

Advertisement