EFD ULTIMUS V User Manual page 41

High precision dispenser
Table of Contents

Advertisement

j: lockout Set Clock/Date Menu selection (CL)
k: lockout Set Communications Menu selection (CO)
n: lockout Alarm Options Menu selection (AM)
2.2.24 Set Language Command
This command changes the language setting of the Ultimus V.
Host Format:
ED--LI: Language Index
0=English
1=French
2=German
3=Spanish
4=Italian
5=Chinese
6=Japanese
7=Korean
2.2.25 Alarm Options Set Command
This command sets the options for all the Ultimus V Alarms. A '1' indicates the alarm feature is
enabled. A '0' indicated that alarm feature is disabled.
Host Format:
EI--INiIOoILlPOpPLbAEeAOa
i: Enable Input Alarm (IN)
o: Enable Output of Input Alarm (IO)
l: Latch the Input Alarm (IL)
p: Enable Output of the Pressure Alarm (PO)
b: Latch the Pressure Alarm (PL)
e: Enable Auto Increment Alarm (AE)
a: Enable Output of the Auto Increment Alarm (AO)
2.2.26 Reset Alarms Command
This command clears any latched alarm in the Ultimus V.
Host Format:
EK--
2.2.27 Dispense Command
This command initiates a dispense cycle in the Ultimus V. If the unit is in timed mode, the unit will
dispense for the duration currently set in dispense time parameter. If the unit is in steady mode, the
unit will begin dispensing. Another dispense command is then needed to end the dispense cycle.
Host Format:
DI-
www.efd-inc.com info@efd-inc.com
USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006
dispensing systems are available worldwide .
Sales and service of EFD
®
APPENDIX B
RS-232
Connection
Protocol
41

Advertisement

Table of Contents
loading

Table of Contents