EFD ULTIMUS V User Manual page 32

High precision dispenser
Table of Contents

Advertisement

APPENDIX A
I/O Connector
Pin Descriptions
Pin 10:
Alarm Output–: This signal is the output of a solid state switch.
The Alarm Out signal is connected by a solid state switch. When an alarm condition occurs, the
dispenser closes the solid state switch, shorting out the Alarm Out pins.
The Alarm Out signal can be activated by the Input Alarm, Pressure Alarm or Auto Increment Alarm.
The Alarm Options LCD screen is used to allow or disallow any of the alarm conditions from
activating the Alarm Out signal.
The circuit is designed to operate between 5 to 24 VDC with a 100mA maximum current.
Note:
A resistor should be placed between the external power source and the Alarm Out+ pin to
limit the current through the Alarm Output circuit to less than 100mA.
DC
Pin 11:
24VDC Power Supply+: This pin will provide 24 VDC, 100mA power to an external load.
Pin 12 to Pin 15:
24VDC Power Supply–: These pins are the 24 VDC power supply reference and return pins.
www.efd-inc.com info@efd-inc.com
32
Alarm Out–
PC/PLC
Vdd Out
Digital Input 0
Digital Input 1
Digital Input 2
Common
Alarm Output to Digital Input
External Relay
Alarm Output to External Indicator
PS+
PS–
USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006
Sales and service of EFD
®
Ultimus V DIO
2.2K
Pin 9: Alarm Out+
Pin 10: Alarm Out-
Ultimus V DIO
2.2K
Pin 5: PS+
Pin 9: Alarm Out+
Pin 10: Alarm Out-
Pin 12: PS-
dispensing systems are available worldwide .