EFD ULTIMUS V User Manual page 27

High precision dispenser
Table of Contents

Advertisement

Dispense Count Mode
Enabling Auto Increment in Dispense Count mode allows the Ultimus V to increase the memory cell
address from the Start Address to the End address based on the number of dispense cycles that occur.
The Shot variable on the main screen tracks the number of dispense cycles for the current memory
address and resets to zero when the memory cell address advances to the next address.
In Count mode, the Trigger value represents the number of dispense cycles that need to occur before
the current memory cell is advanced to the next location. The valid range is 00001 to 99999 dispense
cycles. The total dispense cycle count for the unit is saved and will continue to increment while in Auto
Increment mode.
Time Mode
Enabling Auto Increment in Time Mode will allow the Ultimus V to increment the memory cell address
from the Start Address to the End Address, based on the number of seconds that have elapsed.
When Time mode is selected, the real time clock becomes a counter that counts, in seconds, from
00000 to 99999. The counter resets to all zeros when the memory cell address increments.
In Time mode, the Trigger value represents the amount of time that needs to elapse before the current
memory cell is advanced to the next location. The valid range is 00001 to 99999 seconds.
Auto Sequence Mode
Enabling Auto Increment in Auto Sequence mode allows the Ultimus V to increase the memory cell
address from the Start Address to the End address based on the number of dispense cycles that occur.
The Shot variable on the main screen tracks the number of dispense cycles for the current memory
address and resets to zero when the memory cell address advances to the next address.
As in Count mode, the Trigger value represents the number of dispense cycles that need to occur before
the current memory cell is advanced to the next location. The valid range is 00001 to 99999 dispense
cycles. The total dispense cycle count for the unit is saved and will continue to increment while in Auto
sequence mode.
Once the trigger value is reached for the End address, the Ultimus V will automatically reset the memory
cell address back to the Start address and continue increasing the memory cell address as before. The
auto increment alarm will not be set in this mode.
www.efd-inc.com info@efd-inc.com
USA & Canada 800.556.3484 Europe +44 (0) 1582 666334 Asia & China: +86 (21) 3866 9006
dispensing systems are available worldwide .
Sales and service of EFD
®
Using Auto
Increment
Mode
27