6.3.6
Removal and installation of the cylinder receptacle
1
For removing the cylinder receptacle the steam cylinder must be removed
first (see chapter 6.3.1).
1. Release hose clamps and remove hoses from the connectors.
2. Pressin the locking ring on the end of the check valve, then remove
check valve together with the hose from the corresponding connector
on the cylinder receptacle.
3. Undo the screw fixing cylinder receptacle to the bottom of the housing
with Phillips screwdriver. Then, turn cylinder receptacle counter clockwise
to the stop and remove cylinder receptacle upwards.
4. Remove Oring from the cylinder receptacle.
the installation of the cylinder receptacle follows the reverse sequence.
Before mounting the cylinder receptacle, check Oring for damage and
replace if necessary.
3
4
2
1
55