Removal And Installation Of The Inlet Valve - Nordmann AT4 Operating Instructions Manual

Steam air humidifier
Hide thumbs Also See for AT4:
Table of Contents

Advertisement

6.3.5

Removal and installation of the inlet valve

54
2
1
4
5
3
For removing the inlet valve the steam cylinder must be removed first (see
chapter 6.3.1).
1. Detach electric cables (polarity of the cables must not be observed).
2. Release hose clamp and remove the hose from the connector.
3. Unlock union nut of the water pipe and remove water pipe.
4. Undo the two screws on the bottom of the housing with Phillips screw­
driver, then remove inlet valve.
5. Remove strainer insert with pointed pliers.
the installation of the inlet valve follows the reverse sequence. The union
nut of the water pipe must be tightened by hand only.