522A
822A
brown
black
50
Installation of the steam cylinder follows the reverse sequence. Observe
the following:
–
Before installing the steam cylinder in the unit, check the Oring of the
cylinder receptacle for damage and replace if necessary.
–
Moisten the Oring of the cylinder receptacle with water (do not use
grease or oil), then insert steam cylinder into the socket and push it
down to the stop.
–
Attach the electrode plugs and the level sensor plug to the respective
electrode and sensor connections in accordance with colour code (see
table below).
532A / 534A
832A / 834A
1532A / 1534A
red
sensor
white
brown
sensor
white
–
Fasten steam hose on the connector of the steam cylinder with hose
clamps.
CAUTION!
–
A leaky steam hose can cause damage due to moisture inside the
unit.
–
The outlet connector of the steam cylinder is made of plastic. Do
not overtighten the hose clamp on the steam connector of the
steam cylinder.
Steam cylinder type
2362A / 2364A
3262A / 3264A
black
brown
red
black
brown
sensor
white
4564A / 6564A
black
red
red
brown
black
sensor
white
brown
red
black