Setup - LCD

Figure 4-18. Setup LCD tab
The LCD tab lets you specify which parameters to appear on the display
panel. The display has two rows, the upper row with five characters is for the
measured value and the lower row with six characters for the value name.
The display toggles between the different variables every 2 seconds.
Choose one of the following options:
Table 4-3. LCD parameters
Parameter
Level
Product level.
Distance
Distance from the upper reference point to the product surface.
Volume
Total product volume.
Internal Temperature
Temperature inside the transmitter housing.
Interface Distance
Distance between the upper reference point and the interface
between the upper and lower product.
Interface Level
Level of the lower product.
Interface Thickness
Thicknes of the upper product.
Amplitude Peak 1
Signal amplitude of the reflected signal from the reference pulse.
Amplitude Peak 2
Signal amplitude of the reflected signal from the product surface.
Amplitude Peak 3
Signal amplitude of the reflected signal from the surface of the
bottom product (interface measurements).
Percent Range
Level value in percent of total measurement range.
Analog Output Current
4 -20 mA current.