Chapter 2 ADSL2 Testing
Testing in modem emulate mode
Connecting to
the line
16
It only appears if both of the following conditions exist:
– you are using an ADSL2 SIM that contains the
E.67.5.33 driver (found on the Identity results screen).
– you are using one of the following standards: T.413,
G.DMT, G.lite, Multimode.
Thus, if you are using an ADSL SIM (not ADSL2), or you
are using the ADSL2 or ADSL2+ standard, you will not
see this item.
18 If you are using an Infineon SIM, select Max Rate and
then specify whether the Downstream Max Rate is calcu-
lated with framing overhead or without.
NOTE: Changing this setting will cause the modem to
resync to apply the new setting.
19 If you aree using a TI SIM, select Max Rate S=1/2 and
specify whether to include the S=1/2 calculation for the
Max Rate. If enabled, the max down rate may be
increased beyond 10M.
20 Optional. If you are using a TI SIM and wish to configure
the modem's data pump, select Datapump Config,
specify Custom, and then enter a hexadecimal number
between 0x00000000 and 0xFFFFFFFF. The Default
setting sets the data pump value to 0 for all data pumps
except the 6.00.06.03 data pump which is set to 0x2000.
Select this only if you know it is required.
21 Select Event Log Size, and then specify the size of the
event log. The size options are as follows: 100, 200, 300,
400, 500.
22 If you are using a Conexant SIM and wish to change the
modem driver, use Select Driver to select a driver.
The general modem settings are specified.
After specifying the test settings, you can connect to the line.
HST-3000 ADSL2 Testing User's Guide