Environmental Considerations; Electrical Specifications - Brocade Communications Systems FESX624HF Installation Manual

Fastiron edge x-series
Table of Contents

Advertisement

Hardware Specifications
Power supply specifications

Environmental considerations

TABLE 7
Environmental considerations for power supplies
Property
Operating Environment
Operating temperature
Operating relative humidity
Operating altitude
Operating noise
(based on ISO 7779)
Cooling
Storage Environment
Storage temperature
Storage altitude

Electrical specifications

Table 8
lists the electrical specifications for the power supplies.
TABLE 8
Power supply electrical specification ranges
Description
RPS5 and
RPS-X424
Input Specifications
Input voltage range
100 - 240 VAC
Input current
< 3.5 Amps
Inrush current
< 4.2 Amps peak
maximum
Output Specifications
Output power
220 watts of total output power
80
RPS5, RPS5DC, RPS-X424, and
RPSDC-X424
°
°
°
°
0
to 40
C, 32
to 104
F
0 – 95%, non-condensing
up to 6,600 feet above sea level
47 dB-A
AC: internal fan, 50 mm
DC: internal fan, 60 mm
°
°
°
-40
to +85
C, -40
to 185
up to 15,000 feet above sea level
RPS5DC and
RPSDC-X424
-40 to -60 VDC
< 9 Amps
<10 Amps peak
maximum < 150 ms
(0.15 seconds)
RPS8, RPS8DC, RPSDC-X424-POE,
RPS-FGS, RPS-X424-POE, RPS-X448,
and RPSDC-X448
°
°
°
0
to 40
C, 32
to 104
0 – 95%, non-condensing
up to 10,000 feet above sea level
51 dB-A
internal fans, 50mm
°
°
°
°
F
-40
to +85
C, -40
up to 15,000 feet above sea level
RPS8,
RPS-FGS,
RPS-X424-PO
E, and
RPS-X448
100 to 240
VAC
<8 Amps
< 11.25 Amps
peak maximum
600 watts of total output power, including
+12VDC @ 10A to the system and
-48VDC @ 10 A for Power over Ethernet
ap
Brocade FastIron Edge X-Series Hardware Installation Guide
°
F
°
to 185
F
RPS8-DC,
RPSDC-X424-POE,
and RPSDC-X448
-40 to -60 VDC
<18 Amps
< 26 Amps peak
maximum
Part Number: 53-1002499-02