Brocade Communications Systems FESX624HF Installation Manual page 90

Fastiron edge x-series
Table of Contents

Advertisement

Layer 3 Upgrade Procedures for FastIron IPv4 devices
Detailed procedures
3.
Verify that the Layer 3 software is present in the flash area you specified by entering the following command.
show flash
The "Compressed Pri Code size" or "Compressed Sec Code size" line should list the software. If the software is not correct,
perform
step 2
again.
4.
Enter the following command at the Privileged EXEC level of the CLI to reboot the device using the new software: boot system
flash primary | secondary
where primary or secondary specifies the flash area. Go to
5.
If you normally boot the device from a TFTP or BootP server, enter the following command at the Privileged EXEC level of the
CLI to reboot the device using the new software:
boot system tftp | bootp
NOTE
If you are booting the device from a TFTP server through a fiber connection, use the CLI command boot system tftp
<ip-address> <filename> fiber-port.
6.
Verify that the device booted using the Layer 3 software by observing the boot messages. The "SW" area lists the software
running on the device. You also can display this information by entering the show version command.
90
step
6.
Brocade FastIron Edge X-Series Hardware Installation Guide
Part Number: 53-1002499-02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fesx624hfe-prem6Fesx624e-prem6

Table of Contents