REVISION HISTORY
Page
Description
---
Updated number of Restricted Ground Fault elements in FlexLogic operands table, settings, actual values, features per
product table, Modbus memory map
---
Updated number of Disconnect Breaker Switch elements from 16 to 24 in FlexLogic operands table, settings, features per
product table, Modbus memory map
2-
Updated several specifications, such as TOC, IOC, number of FlexLogic lines
4-30
Added FlexLogic Design and Monitoring using Engineer section to end of Interfaces chapter
5-38
Added PRT FUNCTION settings in Network section to enable/disable each Ethernet port
5-50
Updated IEC 61850 section
5-195
Updated number of FlexLogic lines from 512 to 1024 in FlexLogic Equation Editor settings section
5-225
Updated Zone 1 and 2 ground distance logic diagrams to include IG
11-1
Added Monitoring section
11-2
Added Retrieve Files section
C-
Added Command Line Interface appendix
Table D-5: Major changes for L90 manual version AB2 (English)
Page
Description
D
---
Updated document throughout, for example by checking number of elements that apply to the product
---
Added EAC compliance information throughout, including logo on title page, rear panel, added specifications, added life
expectancy and decommissioning, added sections on Repairs, Storage, and Disposal
---
Updated several figures for consistency
2-
Updated Order Codes and Specifications
2-8
Deleted Functions section
2-29
Added UR Signal Processing section
5-
Updated IEC 61850 content
5-158
Updated FlexLogic Operands table
10-26
Added section 10.3.4 Fast Distance Algorithm
A-
Updated FlexAnalog table
Table D-6: Major changes for L90 manual version AB1 (English)
Page
Description
---
Updated document throughout and put into new template. Major revision.
---
Updated references to digital inputs/outputs to contact inputs/outputs for consistency
---
Added content for advanced IEC 61850, for example in the Settings and Actual Values chapters
2-
Updated Order Codes and Specifications
3-9
Updated Figure 3-9 Typical Wiring Diagram to include delta voltage input options
5-28
Added RS232 Baud Rate setting to Serial Ports section. Baud rate is now configurable, with two options.
5-32
Added Far-End Fault Indication (FEFI) section
9-
Updated conditional text settings in Application of Settings chapter so that content displays for L90
10-2
Added Software Upgrade section to the Maintenance chapter
---
Moved communications appendices B through F to new UR Series Communications Guide for UR 7.3x AB1
C-1
Updated product warranty from 24 months to 10 years
D-4
L90 LINE CURRENT DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL