Rosemount 3051S ERS System
Table A-9. Remote Flanged (RF) Seal Ordering Information
★ The Standard offering represents the most common models and options. These options should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
SN
Grafoil Gasket
SR
Ethylene Propylene Gasket
Additional Options
Standard
(2)
ST
Wetted Materials Compliance per NACE MR 0175 / ISO 1516, MR 0103
SB
Extra Fill Fluid for Cold Temperature Applications
Expanded
(3)
SC
0.006-in. (150 μm) Diaphragm Thickness
(3)
SU
0.001-in. (25 μm) Gold Plated Diaphragm
(4)
SV
PTFE Coated Diaphragm for Non-Stick Purposes
Complete the 3051SAL model number by specifying options as needed:
page A-24 ERS Transmitter Options
(1) Supplied with C4401 Aramid fiber gasket.
(2) Materials of construction comply with metallurgical requirements highlighted within NACE MR0175 / ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(3) Not available with Tantalum diaphragms (Material of Construction codes CC and DC).
(4) Not available with transmitter option code Q8 (Material Traceability per EN 10204 3.1)