Emerson Rosemount 3051S Quick Installation Manual

Electronic remote sensors with hart protocol
Hide thumbs Also See for Rosemount 3051S:

Advertisement

Quick Installation Guide
00825-0100-4804, Rev AB
January 2011
Rosemount 3051S Electronic Remote Sensors
®
with HART
¢00825-0100-4804J¤
www.rosemount.com
Protocol
Step 1: Identify all 3051S ERS
Step 2: Mount Each 3051S ERS Sensor
Step 3: Consider Housing Rotation
Step 4: Set Switches
Step 5: Connect Wiring and Power Up
Step 6: Verify Configuration
Step 7: Calibrate the 3051S ERS System
Product Certifications
Rosemount 3051S ERS System
Start
System Components
End

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Rosemount 3051S

  • Page 1 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 Rosemount 3051S Electronic Remote Sensors ® with HART Protocol Start ™ Step 1: Identify all 3051S ERS System Components Step 2: Mount Each 3051S ERS Sensor Step 3: Consider Housing Rotation...
  • Page 2: Important Notice

    F (65) 6777 0947/65 6777 0743 IMPORTANT NOTICE This installation guide provides basic guidelines for the Rosemount 3051S ERS System (reference manual document number 00809-0100-4804). It does not provide instructions for diagnostics, maintenance, service, or troubleshooting. This document is also available electronically on www.rosemount.com.
  • Page 3 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 1: I 3051S ERS S DENTIFY ALL YSTEMS OMPONENTS A complete 3051S ERS system contains two sensors. One is mounted on the high-pressure ) process connection, and the other is mounted on the low-pressure (P ) process connection.
  • Page 4 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 CONTINUED Horizontal Installation In a horizontal installation, the P sensor should be installed at the upstream process connection. The P sensor should be installed downstream. Figure 2. Horizontal 3051S ERS Installation...
  • Page 5: Mounting Bracket

    Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 CONTINUED Mounting Bracket Figure 3. Mounting bracket assemblies Panel Mount Pipe Mount ™ Coplanar Flange Traditional Flange In-line...
  • Page 6 3051S ERS System. Only use bolts supplied with the transmitter or sold by Emerson Process Management as spare parts. Figure 4 illustrates common transmitter assemblies with the bolt length required for proper transmitter assembly.
  • Page 7: O-Rings With Flange Adapters

    Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 CONTINUED Figure 5. Module Isolator Plate Bolt Sensor Module Isolator Plate Coplanar Flange Flange Adapters Figure 6. Torque Values for the Flange and Flange Adapters Bolts Bolt Material...
  • Page 8: Step 3: Consider Housing Rotation

    Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 3: C ONSIDER OUSING OTATION To improve field access to wiring or to better view the PlantWeb Junction Box optional LCD display: 1. Loosen the housing rotation set screw.
  • Page 9: Step 5: Connect Wiring And Power Up

    Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 5: C ONNECT IRING AND OWER A 3051S ERS System can be wired in a variety of configurations, depending on the hardware that was ordered. Standard 3051S ERS System (Figure 8) 1.
  • Page 10 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 Figure 8. Wiring Diagram for Standard 3051S ERS System...
  • Page 11 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 Figure 9. Wiring Diagram for 3051S ERS System with Remote Display in “Tree” Configuration.
  • Page 12 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 Figure 10. Wiring Diagram for 3051S ERS System with Remote Display in “Daisy-Chain” Configuration.
  • Page 13: Shield Grounding

    Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 Shield Grounding Connect the shield from the 3051S ERS communication cable assembly to each housing case as shown for the applicable wiring configuration in Figure 11. Figure 11. Shield Grounding...
  • Page 14: Power Supply

    Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 Power Supply The DC power supply should provide power with less than two percent ripple. The total resistance load is the sum of the resistance of the two signal leads and the load resistance of the controller, indicator, intrinsic safety barriers, and related components.
  • Page 15 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 The items in Table 2 are considered “optional” and can be configured as necessary: Table 2. Optional Configuration HART Fast Key Sequence Function Fast Key Sequence Device Display...
  • Page 16: Product Certifications

    ERTIFICATIONS Approved Manufacturing Locations Rosemount Inc. – Chanhassen, Minnesota, USA Emerson Process Management GmbH & Co. – Wessling, Germany Emerson Process Management Asia Pacific Private Limited – Singapore Beijing Rosemount Far East Instrument Co., LTD – Beijing, China Emerson Process Management (India) Pvt. Ltd. — Daman, India...
  • Page 17 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 European Certifications ATEX Intrinsic Safety Certificate No. BAX01ATEX1303X II 1G Ex ia IIC T4 (Ta = -60 °C to 70 °C) 1180 Table 4. Input Parameters Loop / Power...
  • Page 18 The 3051S ERS System does not comply with the requirements of EN 60079-1 Clause 5.2, Table 2 for all joints. Contact Emerson Process Management for information on dimensions of flameproof joints. Japanese Certifications...
  • Page 19 3. The 3051S does not comply with the requirements of IEC 60079-1 Clause 5.2, Table 2 for all joints. Contact Emerson Process Management for information on the dimensions of flameproof joints. IECEx Dust Certificate No.
  • Page 20 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 Combinations of Certifications Stainless steel certification tag is provided when optional approval is specified. Once a device labeled with multiple approval types is installed, it should not be reinstalled using any other approval types.
  • Page 21 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 Figure 13. Rosemount 3051S ERS Declaration of Conformity...
  • Page 22 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011...
  • Page 23 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011 Schedule EC Declaration of Conformity RMD 1044 Rev. I PED Directive (97/23/EC) 3051S series Pressure Transmitters Model 3051S_CA4; 3051S_CD2, 3, 4, 5 (also with P9 option) Pressure Transmitters QS Certificate of Assessment EC Certificate No.
  • Page 24 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011...
  • Page 25 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011...
  • Page 26 Quick Installation Guide 00825-0100-4804, Rev AB Rosemount 3051S ERS System January 2011...

Table of Contents