Appendix C
APPROVED
MANUFACTURING
LOCATIONS
ORDINARY LOCATION
CERTIFICATION FOR FM
European Directive
Information
Hazardous Locations
Certifications
Rosemount 3051S ERS System
Product Certifications
Approved Manufacturing Locations . . . . . . . . . . . . . . . . . page C-1
Ordinary Location Certification for FM . . . . . . . . . . . . . . . page C-1
Hazardous Locations Certifications . . . . . . . . . . . . . . . . . page C-1
This section contains hazardous location certifications for 3051S HART protocol.
Rosemount Inc. – Chanhassen, Minnesota, USA
Emerson Process Management GmbH & Co. – Wessling, Germany
Emerson Process Management Asia Pacific Private Limited – Singapore
Beijing Rosemount Far East Instrument Co., LTD – Beijing, China
As standard, the transmitter has been examined and tested to determine that the design meets
basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized
testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health
Administration (OSHA).
Consult your Emerson Process Management sales representative for more information about the
EC declaration of conformity.
North American Certifications
FM Approvals
Explosion-proof for Class I, Division 1, Groups B, C, and D; Dust Ignition-proof for Class II
E5
and Class III, Division 1, Groups E, F, and G; hazardous locations; enclosure Type 4X,
conduit seal not required.
Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Class II, Division 1,
I5
Groups E, F, and G; Class III, Division 1; Class I, Zone 0 AEx ia IIC when connected in
accordance with Rosemount drawing 03151-1306; Non-Incendive for Class I, Division 2,
Groups A, B, C, and D Enclosure Type 4X
For entity parameters see control drawing 03151-1306.
Canadian Standards Association (CSA)
All CSA hazardous approved transmitters are certified per ANSI/ISA 12.27.01-2003.
Explosion-proof for Class I, Division 1, Groups B, C, and D; Dust Ignition-Proof for Class II
E6
and Class III, Division 1, Groups E, F, and G; suitable for Class I, Division 2, Groups A, B, C,
and D, CSA Enclosure Type 4X; conduit seal not required; Dual Seal.
Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D when connected in
I6
accordance with Rosemount Drawings 03151-1316; Dual Seal.
For entity parameters see control drawing 03151-1316.
European Certifications
ATEX Intrinsic Safety
I1
Consult factory for availability.
ATEX Type n
N1
Certificate No. BAS01ATEX3304X
Ex nL IIC T5 (Ta = -40 °C to 70 °C)
Ui = 45 Vdc max
Ci = 11.4 nF
IP66
1180
Special Conditions for Safe Use (X)
The apparatus is not capable of withstanding the 500 V insulation test required by Clause
6.8.1 of EN 60079-15. This must be taken into account when installing the apparatus.
II 3 G
C-1