Kemppi Minarc 150 Operating Manual
Hide thumbs Also See for Minarc 150:

Advertisement

1910150
0901
M
INARC™
150, 151
150 VRD
120 AU, 150 AU
Käyttöohje • Suomi
Bruksanvisning • Svenska
Bruksanvisning • Norsk
Brugsanvisning • Dansk
Operating manual • English
Gebrauchsanweisung • Deutsch
Gebruiksaanwijzing • Nederlands
Manuel d'utilisation • Français
Manual de instrucciones • Español
Instrukcja obsługi • Polski
Инструкции по эксплуатации • По-русски
FI
SV
NO
DA
EN
DE
NL
FR
ES
PL
RU

Advertisement

Table of Contents
loading

Summary of Contents for Kemppi Minarc 150

  • Page 1 1910150 Käyttöohje • Suomi 0901 Bruksanvisning • Svenska Bruksanvisning • Norsk Brugsanvisning • Dansk Operating manual • English Gebrauchsanweisung • Deutsch Gebruiksaanwijzing • Nederlands Manuel d’utilisation • Français Manual de instrucciones • Español Instrukcja obsługi • Polski Инструкции по эксплуатации • По-русски INARC™...
  • Page 3 Operating Manual english...
  • Page 4: Table Of Contents

    COntents prefaCe ............Introduction ......................Safety instructions ..................BefOre yOu start using the unit ..Unpacking ......................Placing the unit ....................Serial number ...................... Main components ..................Connecting to power supply mains ..........Filler materials and equipment ............use .............. Welding processes ..................
  • Page 5: Preface

    There is also information on both servicing the unit as well as its technical data. Read the instructions before taking the machine into use or servicing it for the first time. Additional information on Kemppi products and their use can be obtained from Kemppi or a Kemppi dealer.
  • Page 6 • Never wear the device on the shoulder during welding and never suspend it by the carrying strap during welding. • Do not expose the machine to high temperatures, as heat may cause damage to the machine. • Keep the torch cable and earthing cable as close to each other as possible throughout their length. Straighten any loops in the cables. This minimises your exposure to harmful magnetic fields, which may interfere with a pacemaker, for example. • Do not wrap the cables around the body. • In environments classified as dangerous, only use S-marked welding devices with a safe idle voltage level. These work environments include, for example, humid, hot or small spaces where the user may be directly exposed to the surrounding conductive pieces.
  • Page 7 • Make sure that faulty and damaged welding torches are changed immediately as they can be lethal and may cause electrocution or fire. • Remember that the cable, plugs and other electric devices may be installed or replaced only by an electrical contractor or engineer authorised to perform such operations. • Turn off the welding machine when it is not in use. Welding power circuit • Insulate yourself from the welding circuit by using dry and undamaged protective clothing. • Never touch the work piece and welding rod, welding wire, welding electrode or contact tip at the same time.
  • Page 8 While every effort has been made to ensure that the information contained in this guide is accurate and complete, no liability can be accepted for any errors or omissions. Kemppi reserves the right to change the specification of the product described at any time without prior notice. Do not copy, record, reproduce or transmit the contents of this guide without prior permission from Kemppi.
  • Page 9: Before You Start Using The Unit

    Kemppi Minarc is a manual metal arc welding machine, small in size, suitable for industry, site and repair welding. The unit uses one phase connection voltage and it is manufactured for two different mains voltages: 230 V (Minarc 150) and 110 V (Minarc 151).
  • Page 10: Placing The Unit

    plaCing the unit Place the unit on horizontal, solid and clean surface. Shield it from heavy rain and scorching sun. Make sure that cooling air circulates freely. serial nuMBer Serial number of the unit is marked on the rating plate of the unit. The serial number makes it possible to trace product manufacturing series. You might need the serial number when placing spare parts orders or when planning maintenance.
  • Page 11: Connecting To Power Supply Mains

    COnneCting tO pOWer supply Mains The unit has a mains cable and a wall plug (Note! Minarc 151 (110 V) is delivered without a plug). You can find fuse and cable sizes in the end of these instructions in Technical data. filler Materials anD equipMent See also 2.4. Main components. You can use all electrodes intended for welding with DC. Suitable electrode sizes for the unit are listed in the end of these instructions in Technical data. Use welding specifications given on electrode package. Check that you have selected the correct welding process before starting to weld.
  • Page 12: Use

    NOTE! It is forbidden to weld in places where there is a danger of fire or explosion! WelDing prOCesses 3.1.1 Manual Metal arc welding (MMa) In manual metal arc (MMA) the welding filler material is melted from the electrode to the weld pool. Rate of welding current is selected on the basis of electrode size used and welding position.
  • Page 13 INARC ø 1,6 ø 2,0 ø 2,5 ø3,25 Fe-Rutile 30-60 40-80 50-110 80-140 Fe-Basic 30-55 50-80 80-110 110-140 Main switch and signal light When you turn the main switch to position I, signal light is lit and the unit is ready for welding.
  • Page 14: Welding Selections

    WelDing seleCtiOns 3.3.1 Manual Metal arc welding (MMa) Select welding parameters according to filler manufacturer’s recommendations. 1. Select polarity (+ or -) of welding current cable and return current cable according to filler. Select MMA welding with the switch Select suitable welding current by adjusting potentiometer. 3.3.2 DC tig welding Select welding parameters according to filler manufacturer’s recommendations.
  • Page 15: Storing

    arc is lit move the electrode slowly forwards tilting it to appr. 10-15° pulling angle. If necessary, adjust current value. Shielding gas is used in DC TIG welding. Your dealer will give you advice on choosing gas and equipment. Open the gas valve on the TTM 15V TIG torch. When gas starts to flow, arc is lit by lightly scratching work piece with the tip of the tungsten electrode. When arc is lit, its length is regulated by holding the tip of the tungsten electrode at a suitable distance from the work piece. Move the torch forwards from the starting point, usually in appr. 10-15°...
  • Page 16: Troubleshooting

    The owner of the equipment is obliged to deliver a decommissioned unit to a regional collection centre, per the instructions of local authorities or a Kemppi representative. By applying this European Directive you will improve the environment and human health.
  • Page 17: Ordering Numbers

    OrDering nuMBers Item Ordering number Minarc 150 welding machine (includes earth- and welding cables) 6102150 Minarc 150 welding machine (Denmark) (includes earth- and welding cables) 6102150DK Minarc 151 welding machine (includes earth- and welding cables) 6101151 Minarc 120AU welding machine...
  • Page 18 Welding range MMA 10 A/20,5 V - 140 A/25,6 V 10 A/20,5 V - 140 A/25,6 V TIG 5 A/10 V - 150 A/16 V 5 A/10 V - 150 A/16 V Welding current control stepless stepless Open-circuit voltage 85 V, (VRD 30 V) 85 V Idle power <10 W...
  • Page 19 Welding range MMA 10 A/20,5 V - 110 A/24,4 V 10 A/20,5 V - 140 A/25,6 V TIG 5 A/10 V - 120 A/15 V 5 A/10 V - 150 A/16 V Welding current control stepless stepless Open-circuit voltage 30 V 30 V Idle power <30 W...
  • Page 20: Warranty Policy

    The parts replaced under the terms of this warranty remain the property of Kemppi and must be returned to Kemppi if requested. After a warranty repair, the warranty of the machine or equipment, repaired...
  • Page 22 D-35510 BUTZBACH e-mail: info.ru@kemppi.com Telefax +46 8 590 823 94 DEUTSCHLAND e-mail: sales.se@kemppi.com Tel +49 6033 88 020 KEMPPI, TRADING (BEIJING) COMPANY, Telefax +49 6033 72 528 LIMITED e-mail: sales.de@kemppi.com KEMPPI NORGE A/S Room 420, 3 Zone, Building B, Postboks 2151, Postterminalen No.12 Hongda North Street,...

This manual is also suitable for:

Minarc 120 auMinarc 151Minarc 150 auMinarc 150 vrd

Table of Contents