Function Test Plan - ferrotec CARRERA Operation Manual

High-voltage power supply unit
Table of Contents

Advertisement

High Voltage Power Supply
Type: CARRERA
8.3.1

Function test plan

Emergency stop system (emergency stop buttons)
Mains isolator (main switch)
Check all electric terminal and plug connections
Push buttons and switches on the switch cabinet
Check all plug, screw and clamped joints for firmness
and tighten if necessary
Function check of the electric drives
8.3.2
Inspections
Version 1.3_15 EN
1.
Carry out a visual inspection of the switch cabinet.
Check:
- the wiring for kinks, abrasions and burns,
- the covers and insulation for damage,
- the switch cabinet doors for ease of movement.
2.
Carry out a function test of all subassemblies in setting mode
and in manual mode.
If all the functions work properly, the machine is handed over to
the operating personnel.
Interval for One-Shift System
W
M
½ Y
X
X
X
Y
MIH
X
X
X
49