Operation - ferrotec CARRERA Operation Manual

High-voltage power supply unit
Table of Contents

Advertisement

High Voltage Power Supply
Type: CARRERA
7

Operation

7.1
Operation and displaying elements
´
Version 1.3_15 EN
The high voltage power supply can only be operated by trained
personne.l
1
Fig. 11
Overview of operation and display elements
The operation and displaying elements are found on the front
panel of the high-voltage power supply unit.
.
Ein Main "On/Off" switch
1
is used to switch the high-voltage power supply on and off.
"HV on" LED (green) is lit if the high-voltage power is at
2
least on the level of 70% of the set value of high voltage.
.
"Interlock" LED (green) is lit if the circuit of connected safety
3
contacts is closed.
"Over-temperature" LED (yellow) is lit if the device has been
4
disconnected due to excessive temperature.
"HV short" LED (short circuit – yellow) is lit if the device has
5
been disconnected due to a short circuit
"ARC rate" LED (yellow)
6
Is lit if the device has shut off because of ARC rate
WARNUNG
6 5 4 3 2