ferrotec CARRERA Operation Manual page 37

High-voltage power supply unit
Table of Contents

Advertisement

High Voltage Power Supply
Type: CARRERA
Digital Input:
(15-30V DC
max. 20 mA Input current)
Digital Outputs:
(15-30V DC
max. 20 mA Output current)
Version 1.3_15 EN
Earthing line
Connect the earthing contact X300 of the high-voltage power
-
supply unit to the earthing point of the vacuum chamber.
For this purpose use a cable with cable lugs, green/yellow wire
-
sheathing and the cross-section of 16 mm².
Control Line
The Y-control cable represents the connection of the high voltage
power supply and the genius control unit.
Connect the high voltage power supply the Genius control unit
-
(Analog: connector X302, Digital: plug X303).
The Y-control cable is part of the scope of delivery of the
Genius controller .
If you have bought the high-voltage power supply unit without a
control unit, use common connectors and connect them in
accordance with connector assignment
Pin assignment of the interfaces
Digital interface connector X303: (15-pole Sub-D connector)
PIN1
High Voltage ON
PIN2
High Voltage Status
PIN 3
Reset
PIN 4
Reset
PIN 5
High Voltage ON
PIN 6
Hochspannung vorhanden
PIN 7
Unit O.K.
PIN 8
Unit O.K.
PIN 9
Current limt exeeded
PIN 10
Current limt exeeded
PIN 11
ARC-Error
PIN 12
ARC- Error
PIN 13
Overtemperature
PIN 14
Overtemperature
NOTICE
NOTICE
in
(-)
in
(-)
out
(+)
out
(+)
out
(+)
out
(+)
out
(+)
36