Configurable Parameters; Parameter Overview - CalAmp INTEGRA-TR User Manual

Wireless modem for licensed spectrum
Hide thumbs Also See for INTEGRA-TR:
Table of Contents

Advertisement

4

CONFIGURABLE PARAMETERS

4.1

PARAMETER OVERVIEW

The parameters used to configure the Integra-TR units are described in the Field Programming Software help file. Section 4
summarizes the Integra-TR parameter settings and their variations when used within a network.
Table 11 - Normal Factory Settings (Units)
Fields
Network Settings
Compatibility Mode
Tx/Rx Mode
Extended Preamble (ms)
Network Speed
Tx Online Diagnostics
Unit Type
Data Delivery
Suspend Period (ms)
Activity Time-out (sec)
Sleep Mode
COM Port
Device Baud
Data fwd timer
Xmit Control
DCD Control
External I/O Connector
Frequency
Transmit
Receive
Adjustments
Carrier Sense (-dBm)
Tx Time Out
Disable Tx w/ Carrier Present
Power Out
Transceiver Type
Refer to help files (See section 3.5) for descriptions of the above fields.
Integra-TR with other Integra-TR
Integra-TR
5 mS
19200 Full Channel
9600 Half Channel
2400 Quarter Channel
Yes
Master
All
0
5
Disable (N/A)
19200
Normal
Parity
8 bit, no parity, 1 stop bit
Break
Ignore break
DOX
Switched
I/O 1
Input or Fan Control (units with cooling fan option) Digital Output
(units not equipped with cooling fan option when Modem Board
Rev is 0 or 1)
I/O 2
Input Digital Output to control open-collector transistor (when Modem Board Rev is 0 or
1)
User choice
User choice
105 (116 for quarter-channel)
30 sec ON
Disabled (OFF)
255 (indicates 5 Watts nominal)
Transceiver
Integra-T / TR
Integra-T / TR
Both Tx and Rx
0 mS
9600 Full Channel
9600
110
Integra-TR User Manual
Integra-T
(N/A)
(N/A)
0 mS
Input
Page | 67

Advertisement

Table of Contents
loading

Table of Contents