Network Speed
Network Speed selects the bit rate of the RF link between units. This can be different from the COM Port baud rate. This
setting must be the same for all units in a network.
2400 b/s - selectable for quarter channel models Integra-TR only.
4800 b/s - selectable for quarter, half- and full-channel models of the Integra-TR and for full-channel models of the
Integra-T.
9600 b/s - selectable for half- and full-channel models of the Integra-TR and for full-channel models of the Integra-
T.
19200 b/s - selectable for full-channel models of Integra-TR only.
Tx Online Diags
Transmission of online diagnostics may be enabled or disabled for any unit without affecting its ability to communicate with
other units in a network. At the beginning of each data transmission from a unit, diagnostics are delivered locally to the
unit's Setup Port regardless of the Tx Online Diags setting. Where continuous data transmissions are required from a
Master unit, diagnostics are delivered at 20 second intervals.
Online Diagnostic String Format
In ASCII output mode, the setup port will output a one line diagnostic string each time the unit receives a transmission from
another unit. No other data will be output. The string consists of a number of comma-delimited fields terminated by a
carriage return. Each field within itself is a constant length, but the fields are not all uniform in length. Field definitions are
shown in Table 6.
A typical diagnostic string (0003,+28,13.1,-093,-088,4.7,1,015,015) would be interpreted as: Remote station # 3 reports
that:
Its internal case temperature is +28°C
Supply voltage is 13.1 VDC
It is receiving a signal of -93 dBm from the master
The master is receiving a signal of -88 dBm from station 003
The forward power is 4.7 watts
The reverse power is good
15 of the last 15 data blocks were received correctly

Table 6 - Diagnostics Information

Name
Length (in bytes)
Short ID
Temperature
B+
Remote RSSI
Local RSSI
FWD Power
Rev Power
Rx Quality
Description
4
1 -1023 (a number from 1 to 254, 256 to 1023)
3
Signed value
4
From 6.0 to 18.8 V
4
Signal strength received by remote station in dBm
4
Signal strength for this remote as received by local station in dBm
4
From 0 to 7 watts
1
0 = good 1 = poor
3
Number of good data blocks received in the last 15
3
Number of total data blocks detected, maximum 15