Menu 15: I/O Option Parameters - Control Techniques Commander SK Advanced User's Manual

Ac variable speed drive for 3 phase induction motors from 0.25kw to 4kw, 0.33hp to 5hp
Hide thumbs Also See for Commander SK:
Table of Contents

Advertisement

Introduction
Parameter x.00
description format
9.15

Menu 15: I/O Option parameters

Table 9-20 Menu 15 parameters: single line descriptions
Parameter
15.01
Not used
15.02
Not used
15.03
Current loop loss indicator
15.04
Terminal T5 digital input state
15.05
Terminal T6 digital input state
15.06
Terminal T7 digital input state
15.07
Relay state (Terminals T21 and T23)
15.08
Not used
15.09
Not used
15.10
Not used
15.11
Not used
15.12
Not used
15.13
Not used
15.14
Terminal T5 digital input invert
15.15
Terminal T6 digital input invert
15.16
Terminal T7 digital input invert
15.17
Relay invert
15.18
Not used
15.19
Real time clock day light saving mode
15.20
Digital I/O read word
15.21
Not used
15.22
Not used
15.23
Not used
15.24
Terminal T5 digital input destination
15.25
Terminal T6 digital input destination
15.26
Terminal T7 digital input destination
15.27
Terminal T21/T23 relay source
15.28
Not used
15.29
Drive encoder speed feedback
15.30
Real time clock update mode
15.31
Drive encoder lines per revolution
15.32
Drive encoder revolution counter
15.33
Drive encoder position
15.34
Real time clock minutes/seconds
15.35
Real time clock days/hours
15.36
Real time clock month date
15.37
Real time clock years
15.38
Analog input 1 mode (Terminal T2)
15.39
Analog output 1 mode (Terminal T3)
15.40
Analog input 1 monitor (Terminal T2)
15.41
Analog input 1 scaling (Terminal T2)
15.42
Analog input 1 invert (Terminal T2)
15.43
Analog input 1 destination (Terminal T2)
15.44
Maximum drive encoder reference
15.45
Drive encoder reference scaling
15.46
Drive encoder reference monitor
15.47
Drive encoder reference destination
15.48
Analog output 1 source (Terminal T3)
15.49
Analog output 1 scaling (Terminal T3)
Commander SK Advanced User Guide
Issue Number: 2
Parameter
Keypad and
CT Modbus
display
www.controltechniques.com
User
CT Soft
RTU
programming
Range
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 255
Pr 1.01 to Pr 21.51
Pr 1.01 to Pr 21.51
Pr 1.01 to Pr 21.51
Pr 0.01 to Pr 21.51
-32000 to +32000 rpm
0 to 2
0 to 3
0 to 65535
16
0 to 65535 (1/2
ths of a
revolution)
00.00 to 59.59
1.00 to 7.23
00.00 to 12.31
2000 to 2099
0 to 6
0 to 4
-100% to +100%
0.000 to 4.000
0 to 1
Pr 1.01 to Pr 21.51
0 to 32000 rpm
0.000 to 4.000
-100% to +100%
Pr 1.01 to Pr 21.51
Pr 0.01 to Pr 21.51
0.000 to 4.000
Advanced parameter
Menu 0
descriptions
Default
Setting
0
0
0
0
0
Pr 0.00
Pr 0.00
Pr 0.00
Pr 0.00
0
1
00.00
0.00
00.00
2000
0
0
1.000
0
Pr 0.00
1500
1.000
Pr 0.00
Pr 0.00
1.000
Menu 15
Update Rate
BW
BW
BW
BW
BW
BR
BR
BR
BR
BR
BW
Drive reset
Drive reset
Drive reset
Drive reset
BW
B R/W
BR
BW
BW
B R/W
B R/W
B R/W
B R/W
BR
BR
BW
BR
BR
Drive reset
BR
BR
BW
Drive reset
Drive reset
BR
145