Installation - Honda HRM 520 Owner's Manual

Robotic lawnmower
Table of Contents

Advertisement

Installation

Installation
We strongly recommend that an authorised Honda dealer performs the installation of your Robotic
Lawnmower. Installation by an authorised Honda dealer will ensure that your system is working correctly.
Checking conditions for installation
Check with the dealer that performed the installation if the docking station and boundary wire are installed
according to the conditions below. Also periodically confirm that these conditions are still met.
If any of these conditions are not met, consult your dealer.
It is recommended that the mains power supply is professionally installed in line with local laws and regulations.
Conditions for installing the docking station
5° (8.7%)
5° (8.7%)
Right side wire connector
(Type 0)
Boundary
wire
length
Left side wire
connector
0-800 m
Type 2
Pattern A
More than
More than
2 m
1 m
12
Image
Type 2
Docking direction
CW (Clockwise)
ACW (Anti-clockwise)
Right side wire
Left side wire
connector
connector
Type 0
Type 2
Pattern B
Corner
1 m
0-20 cm
More than
1 m
• The docking station must be installed on a flat
surface with an inclination of no more than 5°
5° (8.7%)
(8.7%).
• The docking station must not be curved.
5° (8.7%)
• The screws must be firmly tightened.
• Before installing the docking station, check the
ground condition which may vary seasonally. It
may be necessary to maintain the ground with
the season.
• If installing the docking station directly on
the lawn, cut the grass on which the docking
station will be located as short as possible.
• Because of a wrong installation of the docking
station, the lawnmower may not be charged.
You need to set the loop direction CW
(Clockwise) or ACW (Anti-clockwise) when the
lawnmower returns to the docking station.
You also need to connect the connectors of the
boundary wire with the terminals of the docking
station with reference to the left table.
NOTE:
- If your lawnmower is HRM310, the max
length of the boundary wire is 400 m.
Right side wire
connector
Type 0
• The boundary wire must be laid according to
the figure on the left (Pattern A or Pattern B).
2 m
• There must be no obstacles as follows:
Pattern A: within 1 m from the station
Pattern B: within 2 m from the station
• There must not be foreign objects within the
work area near the docking station (in the
shaded area indicated in the image).
• The boundary wire under the docking station
must be laid toward the outside of the work
area.
Condition

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hrm 310

Table of Contents