AKD Installation | 9   Electrical Installation

9.12.4 Resolver

The diagram below shows the connection of a resolver (2 to 36-poles) as a feedback system.
The thermal control in the motor is connected via the Resolver cable and evaluated in the
drive. If no thermal control is in the motor, the cable must short pins 8 and 9.
If cable lengths of more than 100 m are planned, please contact customer support.
The pin assignment shown on the Resolver end relates to Kollmorgen motors.
124
Kollmorgen | kdn.kollmorgen.com | October 2017
Type
FBTYPE
Resolver
40
Description
Accuracy: 14 bit (0.022°), resolution: 16 bit (0.006°)