Three Phase Connection (All Akd Types); Single/Dual Phase Connection (Akd-X00306 To Akd-X01206 Only) - Kollmorgen AKD series Installation Manual

Hide thumbs Also See for AKD series:
Table of Contents

Advertisement

9.8.4.1 Three phase connection (all AKD types)

Directly to 3-phase supply network, supply networks (➜ # 103)
Filtering for AKD-xzzz06 to be provided by the user.
Fusing (such as fusible cut-outs) to be provided by the user (➜ # 40).

9.8.4.2 Single/Dual phase connection (AKD-x00306 to AKD-x01206 only)

Directly to single-phase supply network (120 V
Directly to two-phase supply network (120 V
Supply networks(➜ # 103)
Leave L3 open circuit
Filtering to be provided by the user.
Fusing (such as fusible cut-outs) to be provided by the user (➜ # 40)
AKD Installation | 9   Electrical Installation
+10%
to 240 V
-10%
+10%
to 240 V
-10%
Kollmorgen | kdn.kollmorgen.com | October 2017
) with neutral line or
) without neutral line
107