DSX-600 CableAnalyzer
Technical Reference Handbook

Step 3: Turn Off the Auto Save Function

For this tutorial, you will manually save the test results.
3-1
On the home screen, tap the Next ID panel.
3-2
On the CHANGE ID screen, tap the Auto Save control to make
it show Off.
3-3
Tap DONE.

Step 4: Do an Autotest

4-1
Attach the channel adapters to the main and remote testers.
4-2
Turn on both testers, then connect a twisted pair cable
between the adapters.
4-3
Tap TEST on the main tester or press  on the main or
remote tester.

Step 5: Look at the Results

The tester shows the Autotest results in three formats (Figure 12):
WIRE MAP: Shows the connections between the ends of the
cable.
PERFORMANCE: Shows the overall result for each test. Use
this screen to quickly see which test failed.
Plot and tabular results screens: Tap a test on the
PERFORMANCE screen to see a table or plot of the results.
If you set HDTDR/HDTDX to All Autotests, you can see the
analyzers' results on the DIAGNOSTIC tab.