Length Of Twisted Pair Cabling - Fluke DSX-600 Technical Reference Handbook

Cableanalyzer
Hide thumbs Also See for DSX-600:
Table of Contents

Advertisement

DSX-600 CableAnalyzer
Technical Reference Handbook
DSX-600 Level V Accuracy Performance Parameters
Parameter
Directivity
(applicable when
Source Match
Return loss of
Termination
20 - 15log(f/100),
(applicable when

Length of Twisted Pair Cabling

Length specifications do not include the uncertainty of the
cable's NVP value.
Parameter
Range
800 m (2600 ft)
Resolution
0.1 m or 1 ft
 (0.3 m + 2 %); 0 m to 150 m
Accuracy
 (0.3 m + 4 %); 150 m to 800 m
208
per IEC Guidelines (continued)
Baseline Field
Tester
1 to 300 MHz:
27 - 7log(f/100),
30 dB maximum
300 to 500 MHz:
23.7 dB
IL > 3 dB)
20 dB (applicable when IL > 3dB)
1 to 250 MHz:
25 dB maximum
250 to 500 MHz:
14 dB
IL > 3 dB)
Without Remote
Field Tester with
Level V Permanent
Link Adapter
1 to 300 MHz:
25 - 7 log(f/100), 30 dB maximum
300 to 500 MHz: 21.7 dB
(applicable when IL > 3 dB)
1 to 250 MHz:
18 - 15 log(f/100), 25 dB maximum
250 to 500 MHz: 12 dB
(applicable when IL > 3 dB)
Note
Twisted Pair Cabling
Field Tester with
Level V Channel
Adapter
With Remote
150 m (490 ft)
0.1 m or 1 ft
 (0.3 m + 2 %)