Twisted Pair Autotest Results; Pass*/Fail* Results - Fluke DSX-600 Technical Reference Handbook

Cableanalyzer
Hide thumbs Also See for DSX-600:
Table of Contents

Advertisement

DSX-600 CableAnalyzer
Technical Reference Handbook

Twisted Pair Autotest Results

The tests listed below apply to twisted pair cabling.
Some tests are not included in some test limits.
Wire map
Resistance
Length
Propagation delay
Delay skew
Insertion loss (attenuation)
Impedance
NEXT (near-end crosstalk)
PS NEXT (power-sum near-end crosstalk)
ACR-N (attenuation to crosstalk ratio at the near end)
PS ACR-N (power-sum attenuation to crosstalk ratio, near
end)
ACR-F (attenuation to crosstalk ratio at the far end)
PS ACR-F (power-sum attenuation to crosstalk ratio, far end)
Return loss
HDTDR and HDTDX analyzers (optional tests, not required by
any test limit. See Chapter 6.)

PASS*/FAIL* Results

A result shows an asterisk when measurements are in the tester's
accuracy uncertainty range (Figure 20) and the asterisk is required
by the selected test limit. These results are marginal.
A PASS* shows that the cable's performance is
satisfactory. If a cable must get a PASS result to agree with
your requirements for quality, identify and correct the
problems with the cable and do the Autotest again.
58
Note