Fluke DSX-600 Technical Reference Handbook page 69

Cableanalyzer
Hide thumbs Also See for DSX-600:
Table of Contents

Advertisement

Table 2. Settings for Twisted Pair Tests (continued)
Setting
Test Limit
Store Plot Data
HDTDR/HDTDX
Select the correct test limit for the job. To see a different
group of limits, tap MORE, then tap the name of a
group.
Off
: The tester does not save plot data for
frequency-domain tests or for the HDTDR/HDTDX
analyzers. You can see the plots before you save the test
and exit the results screen. The saved results show
frequency-domain measurements in a table and do not
include the HDTDR/HDTDX plots.
On
: The tester saves plot data for all frequency-
domain tests required by the selected test limit and for
the HDTDR/HDTDX analyzers.
Fail/Pass* only: The tester shows HDTDR and HDTDX
analyzer results only for Autotests with PASS*, FAIL*, or
FAIL results.
All Autotests: The tester shows HDTDR and HDTDX
analyzer results for all Autotests.
To get HDTDR/HDTDX analyzer results you can also tap
Tools > Diagnostics.
For more information about the HDTDR and HDTDX
analyzers, see Chapter 6.