Autotest on Twisted Pair Cabling
1
Attach adapters appropriate for the job to the tester and the smart remote.
2
Turn the rotary switch to SETUP, then select Twisted Pair. Set the following on the
Twisted Pair tab:
Cable Type: Select a list of cable types; then select the cable type to be tested.
Test Limit: Select the test limit required for the job. The screen shows the last nine
limits used. Press
3
Turn the rotary switch to AUTOTEST and turn on the smart remote. Connect to the
cabling as shown in Figure 3 or 4.
4
Press
on the tester or smart remote. To stop the test at any time, press
5
The tester shows the Autotest Summary screen when the test is complete (Figure 5). To
view results for a specific parameter, use
then press
6
If the Autotest failed, press
7
To save the results, press
More to see other lists of limits.
.
Fault Info for possible causes of the failure.
. Select or create a cable ID; then press
Figure 3. Channel Test Connections
to highlight the parameter;
.
again.
Y02.EPS