SECTION 3 - MACHINE CONTROLS AND INDICATORS
TO AVOID SERIOUS INJURY, DO NOT OPERATE MACHINE IF ANY CONTROL LEVERS OR
TOGGLE SWITCHES CONTROLLING PLATFORM MOVEMENT DO NOT RETURN TO THE
OFF POSITION WHEN RELEASED.

Ground Control Station

See Figure 3-1., Ground Control Station and Figure 3-2., Ground Control
Station with Machine Safety System Override (MSSO) (CE Only)
1. Indicator Panel
The Indicator Panel contains indicator lights that signal
problem conditions or functions operating during machine
operation.
NOTE:
The Function Enable switch must be held down in
order to operate Main Boom Telescope, Tower Lift,
Swing, Main Lift, Jib Lift, Platform Level Override,
and Platform Rotate functions.
3-2
2. Hourmeter
Registers the amount of time the machine has been in use,
with engine running. The hourmeter registers up to 9,999.9
hours and cannot be reset.
WHEN THE MACHINE IS SHUT DOWN THE POWER/EMERGENCY STOP SWITCH MUST BE
POSITIONED TO THE OFF POSITION TO PREVENT DRAINING THE BATTERIES.
3. Power/Emergency Stop Switch
A two-position red mushroom shaped switch supplies
power to PLATFORM/GROUND SELECT switch when pulled
out (on). When pushed in (off ), power is shut off to the PLAT-
FORM/GROUND SELECT switch.