JLG 340AJ Operation And Safety Manual page 107

Boom lift
Hide thumbs Also See for 340AJ:
Table of Contents

Advertisement

3. Hydraulic Tank
Lube Point(s) - Fill Cap
Capacity - 24.8 Gal. (93.9 L), 20.6 Gal. (77.9 L) to Full Level; 17.8
Gal (67.4 L) to Low Level
Lube - HO
Interval - Check Level daily; Change every 2 years or 1200
hours of operation.
Comments - On new machines, those recently overhauled, or
after changing hydraulic oil, operate all systems a minimum
of two complete cycles and recheck oil level in reservoir.
3121258
SECTION 6 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
4. Hydraulic Tank Return Filter and Breather
Interval - Change after first 50 hrs. and every 6 months or 300
hrs. thereafter.
Comments - For breather element, twist top to replace. Under
certain conditions, it may be necessary to replace both ele-
ments on a more frequent basis.
– JLG Lift –