Installation And Wiring - Hitachi P1-00080-L Basic Manual

Sj series
Hide thumbs Also See for P1-00080-L:
Table of Contents

Advertisement

Chapter 2
Chapter 2

Installation and Wiring

2.1 Check the Inverter
Check the contents in the package, and confirm the
inverter model with a specification label.
Inverter
The model of the product is as follows:
E.g.: 200V class input voltage for Japan
Applicable motor capacity for ND rating is 3.7kW
ND rated current 17.5A
LD rated current 19.6A
VLD rated current 22.8A
00228
P1 -
(2)
(3)
(1) Series name P1
(2) Motor maximum rated current (at VLD rated current
00001: 0.1A to 99999: 9999.9A
(3) Input power specification
L: three-phase 200V class;
H: three-phase 400V class
(4) Panel
B: no operator keypad equipped;
F: panel equipped
(5) Region (None): Japan;
E: Europe/Southeast Asia;
U: North America;
C: China
In case of (None), blank field is omitted.
(6) Integrated noise filter
F: integrated noise filter equipped;
CB: conduit box equipped
When both F and CB are equipped, it is indicated as
FCB.
Specification label example
Description example for P1-00228-LFF
(*) means eigenvalues
Inverter model
Input ratings
(Frequency/voltage/No. of
phases/Current)
Output ratings
(Frequency/voltage/No. of
phases/Rate current)
MFG No.; factory serial No.
Basic Guide
(This document)
-
L
F
F
(4) (5) (6)
(6)
Wire separation plate
SJ series type P1
Model: P1-00228-LFF
Input/Entrée:50Hz,60Hz 200–240V 3ph 27.1/23.3/20.8A
Output/Sortie:0-590Hz 200–240V 3ph 22.8/19.6/17.5A
MFG No. 62AA****** BB001
Configuration and description contents vary
depending on the model.
Refer to User's Guide for more details.
If optional products are included with shipment,
optional instruction will be enclosed.
Functional Safety
Guide
P1-00228-LFF example illustration in below.
Optional slots
 Refer to each optional product
instruction for detail.
Operator keypad
USB (Micro-B)
Control circuit
terminal block
Backing plate
Terminal block
cover
INVERTER
Hitachi Industrial Equipment
MADE IN JAPAN
Systems Co., Ltd.
2-1
Installation and Wiring
Eye bolts for hanging the inverter
P1-01850L/-00930H or above
(enclosed in the package)
Heat sink
Main circuit
terminals
Specification label
Ver.2.00
Date:****
NE18361-***

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents