Hitachi P1-00080-L Basic Manual page 86

Sj series
Hide thumbs Also See for P1-00080-L:
Table of Contents

Advertisement

Chapter 4
[CA-60]~[CA-84]
[FUP]/[FDN] operations
Code/Name
CA-60
FUP/FDN overwrite
target selection
CA-61
FUP/FDN data save
enable
CA-62
UDC terminal mode
selection
CA-64
Acceleration time for
FUP/FDN function
CA-66
Deceleration time for
FUP/FDN function
・[CA-60] sets as operation target the frequency reference
or the PID target value for 020[FUP]/021[FDN].
・[CA-61] sets if the modified values of [FUP] / [FDN]
should be saved or not in the storage memory.
・[CA-62] selects the frequency in which will change the
frequency reference for when [UDC] terminal is ON.
・If [FUP]/[FDN] is turn ON, in the case the frequency
reference is changed you can set the acceleration and
deceleration time [CA-64][CA-66].
[F-OP] Speed/Operation change
Code/Name
CA-70
Speed command
selection when [F-OP] active
CA-71
Operation command
reference selection when
[F-OP] active
・If Intelligent input terminal 023[F-OP] is ON the change
is carried out.
*1)01(Ai1 terminal)/02(Ai2 terminal)/03(Ai3 terminal)/ 07(Parameter)/ 08(RS485)/
12(Pulse train input:main)/14(EzSQ function)/15(PID result)
*2) 00([FW]/[RV] terminal)/01(3-wire)/02(Keypad's RUN key)/03(RS485)
Reset terminal [RS]
Code/Name
00(Trip release at turn-ON)/
CA-72
01(Trip release at turn-OFF)/
Reset mode
02(Effective only in trip ON condition)/
selection
03(Effective only in trip OFF condition)
・The reset terminal usually if is ON cuts the output, but it
also can be made to only operate in trip event.
Main encoder input
Code/Name
CA-81
Encoder constant setting
CA-82
Encoder phase selection
CA-83
Numerator of the
motor gear ratio
CA-84
Denominator of
the motor gear ratio
・Sets the main encoder input and the motor gear ratio
involved in the encoder feedback.
Initial
Range (unit)
value
00(Speed reference)
00
01(PID)
00(No save)/
00
01(Save)
00(0Hz)/
00
01(Save data)
30.00
0.00~3600.00(s)
30.00
Initial
Range (unit)
value
01~03、 07、 08、 12、 14、
01
15 *1)
01
00~03 *2)
Initial
Range (unit)
value
Range (unit)
Initial value
0~65535(Pls)
1024
00(Phase A, Cos lead)/
00
01(Phase B, Sin lead)
1
1~10000
1~10000
1
For parameter configuration
Pulse train input terminal
Code/Name
CA-90
Detection method
selection
CA-91
Mode selection
CA-92
Scale
CA-93
Filter time constant
CA-94
Bias value
CA-95
Upper limit
CA-96
Detection
Lower limit
・A pulse train is introduced in functions [PLA][PLB]
assigned to terminals A,B. If [CA-90]=01, pulses in
terminals A & B are counted. Only terminal A in case
that is a single phase input.
Pulse train counter
Code/Name
CA-97
Pulse counter compare output
ON level
CA-98
Pulse counter compare output
OFF level
CA-99
Pulse counter compare output maximum
value
・Set 091[PCMP] to output the compare results of the
pulse train counters of functions 103[PLA]/104[PLB].
・Turning 097[PCC] terminal in ON state resets the
counter.
・In the following example, when [CA-81]=01, inputting a
00
pulse train in terminal A.
Internal counter
Max. count value
[CA-79]
OFF level [CA-78]
ON level [CA-77]
0
[PLA] input
[PCC] input
[PCMP] output
4-38
[CA-90]~[CA-99]
Initial
Range (unit)
value
00(Frequency reference)/
01(Pulse count)/
feedback :
02(Speed
sensor-V/f)
00(90º-phase-shift)/
01(Forward/reverse
operation and direction of
rotation)/
02(Forward/reverse
operation with pulse train)
25.0
0.05~32.0(kHz)
0.01~2.00(s)
0.10
-100.0~100.0(%)
0.0~100.0(%)
100.0
0.0~100.0(%)
Initial
Range (unit)
value
0~65535
0~65535
0~65535
65535
00
00
0.0
0.0
0
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents