Chapter 2

2.12 Residual risk

Parts subject to residual risk
Please check for any residual risk upon completion of the
installation before power on.
■Residual risk checklist No.
No.
Name of part
Main circuit
(A)
terminal block
(B)
Heat sink
Input/output
(C)
terminal block
Unspecified
parts
Residual risk checklist
Operational
No.
Work
phase
1
Installation
Installation
2
Installation
Installation
3
Installation
Installation
4
Installation
Installation
5
Installation
Installation
6
Installation
Installation
7
Installation
Installation
Installation
8
Wiring
Maintenance
Installation
9
Wiring
Maintenance
Use
Wiring
10
Maintenance
Inspection
Use
Wiring
11
Maintenance
Inspection
The installation, wiring and setting work must be
conducted by qualified engineers.
DANGER
WARNING
8,10
4
11,12
9
Residual
Part
Details of harm or damage
risk
(B)
CAUTION
Damage due to rough transportation.
Shortened lifetime of parts due to the use
in places where the product is exposed to
CAUTION
direct sunlight or the temperature is not
within the specified range.
Short-circuit failure due to the use in
places where the temperature is not
CAUTION
within the specified range or
condensation occurs.
A cooling fan reaching a high temperature
(B)
DANGER
exceeding 150 °C causes a fire on a
flammable wall.
Damage to parts due to entry of dust and
CAUTION
corrosive gases.
Shortened lifetime of parts due to
CAUTION
reduced cooling capability by placing the
product horizontally.
A cooling fan failed due to waterdrops or
CAUTION
oil mist when the heat sink is positioned
outside.
A fire is caused inside by an arc due to
(A)
DANGER
screws loosened by vibrations.
A fire from flammable materials caused
DANGER
by an arc due to screws loosened by
vibrations.
Electric shock by touching a high voltage
(A)
DANGER
part with the cover removed.
Electric shock by touching a high voltage
(C)
DANGER
part with a tool with the cover removed.
(C)
CAUTION
1
2,3,5,6,7
Do not let the product fall. Do not apply
force when handing the cover and
operator keypad.
Verify that the ambient temperature is
within the specified range throughout the
year by means of cooling or ventilation.
Verify that the ambient temperature is
within the specified range throughout the
year by means of cooling or ventilation.
Install the product in places where no
condensation occurs.
Install the product on a non-flammable
metal wall.
Install the product inside a totally
enclosed panel.
Install the product vertically.
With the heat sink positioned outside,
install the product in places free from
waterdrops and oil mist.
Regularly check the tightening of screws.
Regularly check the tightening of screws.
Do not place flammable materials near
the product.
Do not open the cover when the power is
on. Wait for 10 minutes or more after the
power is off, and then confirm that the
voltage between P and N is significantly
less than 45Vdc to start the work.
Do not open the cover when the power is
on. Wait for 10 minutes or more after the
power is off, and then confirm that the
voltage between P and N is significantly
less than 45Vdc to start the work.
2-23
Installation and Wiring
(A)
Preventive measures
(B)