Hitachi P1-00080-L Basic Manual page 28

Sj series
Hide thumbs Also See for P1-00080-L:
Table of Contents

Advertisement

Chapter 2
2.7 Applicable circuit breaker
 200V class
• For ND rating
Model
Applicable
P1-*******
Motor
(P1-****)
(kW)
P1-00044-L(P1-004L)
0.4
P1-00080-L(P1-007L)
0.75
P1-00104-L(P1-015L)
1.5
P1-00156-L(P1-022L)
2.2
P1-00228-L(P1-037L)
3.7
P1-00330-L(P1-055L)
5.5
P1-00460-L(P1-075L)
7.5
P1-00600-L(P1-110L)
11
P1-00800-L(P1-150L)
15
P1-00930-L(P1-185L)
18.5
P1-01240-L(P1-220L)
22
P1-01530-L(P1-300L)
30
P1-01850-L(P1-370L)
37
P1-02290-L(P1-450L)
45
P1-02950-L(P1-550L)
55
• For LD/VLD rating
Model
Applicable
P1-*******
Motor
(P1-****)
(kW)
P1-00044-L(P1-004L)
0.75
P1-00080-L(P1-007L)
1.5
P1-00104-L(P1-015L)
2.2
P1-00156-L(P1-022L)
3.7
P1-00228-L(P1-037L)
5.5
P1-00330-L(P1-055L)
7.5
P1-00460-L(P1-075L)
11
P1-00600-L(P1-110L)
15
P1-00800-L(P1-150L)
18.5
P1-00930-L(P1-185L)
22
P1-01240-L(P1-220L)
30
P1-01530-L(P1-300L)
37
P1-01850-L(P1-370L)
45
P1-02290-L(P1-450L)
55
P1-02950-L(P1-550L)
75
 Device model name on above table shows example selection. The
device selection should be made in base on rated current, short
circuit current capability and accordance to the local electrical
legislation.
 Applicable motor capacity is based on Hitachi 200Vac, 60Hz, 4 pole
IE3 motor.
 Refer to the wire gauge table on chapter 2-8 for power line cable.
Applicable devices (Input Voltage 200~220V)
Without reactor
(DCL or ACL)
Earth-leakage breaker
Magnetic Contactor
(ELB)
Example
Current
AC-1
model
Rate
EB-30E
5
HS8
EB-30E
10
HS8
EB-30E
15
HS8
EB-30E
20
HS8
EB-30E
30
HS8
EB-50E
40
HS20
EB-50E
50
HS35
EB-100E
75
HS50
RXK125-S
125
H65C
RXK125-S
125
H80C
EXK225
150
H80C
EXK225
200
H125C
RXK250-S
250
H150C
EX400
300
H200C
EX400
400
H200C
Applicable devices(Input Voltage 200~220V)
Without reactor
(DCL or ACL)
Earth-leakage breaker
Magnetic Contactor
(ELB)
Example
Current
AC-1
model
Rate
EB-30E
10
HS8
EB-30E
15
HS8
EB-30E
20
HS8
EB-30E
30
HS8
EB-50E
40
HS20
EB-50E
50
HS35
EB-100E
75
HS50
RXK125-S
125
H65C
RXK125-S
125
H80C
EXK225
150
H80C
EXK225
200
H125C
RXK250-S
250
H150C
EX400
300
H200C
EX400
400
H200C
EX600B
500
H300C
2-10
Earth-leakage breaker
(MC)
(ELB)
Example
AC-3
model
HS8
EB-30E
HS8
EB-30E
HS8
EB-30E
HS8
EB-30E
HS20
EB-30E
HS25
EB-30E
HS35
EB-50E
H65C
EB-100E
H80C
EB-100E
H100C
EB-100E
H125C
RXK125-S
H150C
EXK225
H200C
EXK225
H250C
EXK225
H300C
EX400
Earth-leakage breaker
(MC)
(ELB)
Example
AC-3
model
HS8
EB-30E
HS8
EB-30E
HS8
EB-30E
HS20
EB-30E
HS25
EB-30E
HS35
EB-50E
H65C
EB-100E
H80C
EB-100E
H100C
EB-100E
H125C
RXK125-S
H150C
EXK225
H200C
EXK225
H250C
EXK225
H300C
EX400
H400C
EX400
 Electrical endurance for AC-1 magnetic contactor is 500000 times,
however, for emergency stop in motor operation will be only 25
times.
 Select AC-3 class magnetic contactor for inverter output for
application which has an emergency stop or commercial power line
operation.
 When selecting oversize inverter capacity compare to motor rating,
select according to the inverter capacity
Installation and Wiring
With reactor
(DCL or ACL)
Magnetic Contactor
(MC)
Current
AC-1
AC-3
Rate
5
HS8
5
HS8
10
HS8
15
HS8
20
HS8
HS20
30
HS8
HS20
40
HS20
HS25
60
HS35
HS50
100
HS50
H65C
100
HS50
H65C
125
H65C
H80C
150
H80C
H125C
200
H100C
H125C
225
H125C
H150C
300
H150C
H250C
With reactor
(DCL or ACL)
Magnetic Contactor
(MC)
Current
AC-1
AC-3
Rate
5
HS8
10
HS8
15
HS8
20
HS8
HS20
30
HS8
HS20
40
HS20
HS25
60
HS35
HS50
100
HS50
H65C
100
HS50
H65C
125
H65C
H80C
150
H80C
H125C
200
H100C
H125C
225
H125C
H150C
300
H150C
H250C
400
H200C
H300C
HS8
HS8
HS8
HS8
HS8
HS8
HS8