Troubleshooting - Hitachi P1-00080-L Basic Manual

Sj series
Hide thumbs Also See for P1-00080-L:
Table of Contents

Advertisement

Chapter 4
4.1.3.2 3 lines monitor
To change the monitor details.
RUN
FW
Output frequency
Output frequency
Input terminal monitor
Menu
oFW
Press the SEL (O) key while on the 3 lines screen,
highlighting the first line as result.
RUN
FW
Output frequency
Output current
Input terminal monitor
Menu
oFW
Then with UP/DOWN (
one desired of the three monitors.
Pressing the SEL (O) key, the code can be accessed.
RUN
FW
dA-01
Output frequency
Back
oFW
Making use of UP/DOWN/LEFT/RIGHT (
the code of the parameter to be monitored can be
changed, and then with the SEL (O) key confirm the
change. Press 1 key to return back.
M1
H01
46.49 Hz
11.9 A
LLLLLLLLLLL
46.49
Option
M1
H01
46.49Hz
11.9 A
LLLLLLLLLLL
46.49
Option
) is possible to highlight the
M1
H01
29.51 Hz
46.49
Option
) keys,
For parameter configuration
4.1.3.3 Trip history screen
On tripping event.
TRIP
NRDY
Trip event
Overcurrent error
E001 16/12/25 22:15
Output frequency : +29.51 Hz
Output current
DC voltage
Status 1
Menu
oFW
With UP/DOWN (
confirmed. Also, the background will become red.
Trip history.
TRIP
NRDY
Trip history
Total count
1. E001 16/12/25 22:15
2. E007 16/12/25 20:33
3. E009 16/12/02 17:24
4. E012 16/10/10 08:50
5. E001 16/09/21 14:43
Menu
oFW
In the Trip history screen press the SEL (O) key, and with
UP/DOWN (
) keys highlight a history, then press SEL
(O) key to access the details regarding that trip status.
*) For more details about the detailed history, please refer
to "Chapter 5 Troubleshooting".
*) Put a battery for using clock function.
4-4
M1
H07
: 47.71 A
: 290.2 Vdc
: Run
46.49
----
) keys, the trip status can be
M1
H06
18 times
46.49
Detail