Hitachi P1-00080-L Basic Manual page 22

Sj series
Hide thumbs Also See for P1-00080-L:
Table of Contents

Advertisement

Chapter 2
2.3 Dimension Drawing
 If you add optional parts to the inverter, some extra
space is required in the direction of the depth of the
inverter depending on the wiring layout. Keep a
clearance of 50 mm or more. For details, refer to the
instruction manual for each optional product.
Model P1-*****-* (P1-*****-*)
200V class: 00044-L(004L), 00080-L(007L),
0104-L(015L),00156-L(022L), 00228-L(037L)
400V class: 00041-H(007H),00054-H(015H), 00083-H(022H),
00126-H(037H)
W(mm)
Dimension
150
Model P1-*****-* (P1-*****-*)
200V class: 00330-L(055L), 00460-L(075L), 00600-L(110L)
400V class: 00175-H(055H), 00250-H(075H),00310-H(110H)
W(mm)
Dimension
210
H(mm)
D(mm)
255
140
H(mm)
D(mm)
260
170
2-4
(Eg.) See "Chapter 7 Specifications" for details.
VLD rated current for 00046-L(004L) is 4.6A,
(ND rated motor capacity is 0.4kW), and L indicates 200V
class, while H indicates 400V class.
Model (P1-*****-*)
200V class:
00800-L(150L), 00930-L(185L), 01240-L(220L)
400V class:
00400-H(150H), 00470-H(185H), 00620-H(220H)
W(mm)
Dimension
245
Model P1-*****-* (P1-*****-*)
200V class: 01530-L(300L)
400V class: 00770-H(300H)
W(mm)
Dimension
540
Installation and Wiring
H(mm)
D(mm)
390
190
H(mm)
D(mm)
300
195

Hide quick links: