Setting the Display Parameter & Intensity (dsplay)
The upper display ( line 1 ) can be programmed to display:
4.
Rate value
5.
Total or grand total
6.
Toggle rate/total
7.
Toggle rate/G-total
8.
Relay set points
9.
Toggle rate and units
10. Toggle total and units
11. Toggle grand total and units
12. Max, min, or max & min values
13. Modbus input
The lower display ( line 2 ) can be programmed to display:
1.
Engineering units or custom legends for the upper display
2.
Rate value
3.
Total or grand total
4.
Toggle rate/total
5.
Toggle rate/G-total
6.
Relay set points
7.
Toggle rate and units
8.
Toggle total and units
9.
Toggle grand total and units
10. Max, min, or max & min values
11. Modbus input
12. Off (no display)
Selecting engineering units or custom legends as the lower display
( d unit ) will display the unit or tag selected for the rate, total, or grand
total displayed in the Upper display.
For example, if the upper display is set to total , selecting d unit to
display on the lower display will have the total appear on the upper
display, and the total unit appear on the lower display.