5.1.3

Parameter assignment of module

5.1.3.1

Parameter setting (hardware configuration) Opening (TM Count and TM PosInput)

Proceed as follows:
1. Open the device configuration of the CPU or IM.
2. Select the device view.
3. Right-click on the technology module and select "Parameters".
5.1.3.2

Parameter setting (hardware configuration) Opening (Compact CPU)

Proceed as follows:
1. Open the device configuration of the Compact CPU.
2. Select the device view.
3. Right-click on the CPU section of the Compact CPU and select "Parameters".
5.1.4
Online & diagnostics module
5.1.4.1

Displaying and evaluating diagnostics

The online and diagnostics view enables hardware diagnostics. You can also
● Obtain information on the technology module (e.g., Firmware version and serial number)
● Execute a firmware update if required
Procedure (TM Count and TM PosInput)
To open the display editor for the diagnostic functions, follow these steps:
1. Open the "Local modules" or "Distributed I/O" folder in the project tree.
2. Open the technology module in the project tree.
3. Double-click on the "Online & diagnostics" object.
4. Select the required display in the diagnostics navigation.
Procedure (Compact CPU)
To open the display editor for the diagnostic functions, follow these steps:
1. Open the Compact CPU folder in the project tree.
2. Double-click on the "Online & diagnostics" object.
3. Select the required display in the diagnostics navigation.
Counting, measurement and position detection
Function Manual, 12/2017, A5E32009889-AG
Using the module
5.1 Using the technology module