Brother RH-9820 Service Manual page 229

Electronic eyelet button holer
Hide thumbs Also See for RH-9820:
Table of Contents

Advertisement

Upper shaft motor-related errors
Code
E110
Needle up stop position error
E111
Needle up stop position error
E120
Needle drop signal could not be detected.
Sewing machine motor stopped due to a
E130
problem, or synchronizer is faulty.
E131
Synchronizer is faulty.
Problem detected with sewing machine motor
E132
operation.
Sewing machine motor stopping position is
E133
incorrect.
Sewing machine motor operated in reverse
E140
during sewing.
Sewing machine motor is overheating, or
E150
temperature sensor is faulty.
Cause
Remedy
Turn the upper shaft pulley until the point where the error
display disappears.
If the error display does not disappear, turn off the power
and check the connection of the synchronizer connector
P5 at the power supply motor P.C. board.
Turn off the power, and check the connection of the
synchronizer connector P5 at the main P.C. board.
Turn off the power, and check the connection of the
synchronizer connector P5 at the main P.C. board.
Turn off the power, and then turn the upper shaft pulley
and check if the sewing machine has locked up.
Check that the upper shaft motor connector P4 and
synchronizer connector P5 are connected at the power
supply motor P.C. board.
Turn off the power, and check the connection of the
synchronizer connector P5 at the power supply motor P.C.
board.
Turn off the power, and then turn the upper shaft pulley
and check if the sewing machine has locked up.
Check that the upper shaft motor connector P4 and
synchronizer connector P5 are connected at the power
supply motor P.C. board.
Turn off the power, and then turn the upper shaft pulley
and check if the sewing machine has locked up.
Check that the upper shaft motor connector P4 and
synchronizer connector P5 are connected at the power
supply motor P.C. board.
Turn off the power, and then turn the upper shaft pulley
and check if the sewing machine has locked up.
Check that the upper shaft motor connector P4 and
synchronizer connector P5 are connected at the power
supply motor P.C. board.
Turn off the power, and then turn the upper shaft pulley
and check if the sewing machine has locked up.
Check that the upper shaft motor connector P4 and
synchronizer connector P5 are connected at the power
supply motor P.C. board.
RH-9820
9. ERROR CODES
Page
201
217
201
217
201
216
217
201
217
201
217
201
201
201
201
220

Hide quick links: