6. ASSEMBLY

6-24. Routing the air tubes

Cutter cylinder
Insert the air tubes (No. 5 and No. 6) of the cutter cylinder (a) into the elbows (b) in the bed base.
* Insert the air tubes into the elbows (b) with the same numbers.
Upper thread cutter cylinder
1) Pass the air tubes (No. 13 and No. 14) of the upper thread cutter cylinder (c) through the hole in the bed
and out through the bottom.
2) Secure the air tubes with the cord holder (d).
3) Pass the air tubes (No. 13 and No. 14) through the hole in the bed as shown in the illustration below.
4) Pass the air tubes (No. 13 and No. 14) out through the bottom of the bed into the side of the arm, and
then pass them out through the side of the arm.
131
RH-9820
(Left side of arm)
1065B
1066B
1067B
1068B