Verifying 2.5-Gbps Transponder Module Power Status - Cisco ONS 15540 ESPx Hardware Installation Manual

Extended services platform
Hide thumbs Also See for ONS 15540 ESPx:
Table of Contents

Advertisement

Installing and Removing Modules

Verifying 2.5-Gbps Transponder Module Power Status

Cisco ONS 15540 ESPx Hardware Installation Guide
2-34
To verify the status of the power to a 2.5-Gbps transponder module, use the
following privileged EXEC command:
Command
show hardware linecard slot
Example
The following example shows how to display the power status of the subcards in
a 2.5-Gbps line card motherboard:
Switch# show hardware linecard 8
-------------------------------------------------------------------
Slot Number
Controller Type
On-Board Description
Orderable Product Number: N/A
Board Part Number
Board Revision
Serial Number
Manufacturing Date
Hardware Version
RMA Number
RMA Failure Code
Functional Image Version: 2.55
Subcard Power Control
<Information deleted.>
Chapter 2
Purpose
Displays hardware information for a
specific slot in the shelf.
: 8/*
: XpndrMotherboard
: TRANSPONDER_MOTHER_PHASE_0
: 73-5813-05
: 05
: CAB0517HLRV
: 03/30/2001
: 5.1
: 0x00
: 0x00
: 0:ON, 1:OFF, 2:ON, 3:ON
Installing the Cisco ONS 15540 ESPx