32-Channel Terminal Mux/Demux Module Specifications

32-Channel Terminal Mux/Demux Module
Specifications
Warning
Cisco ONS 15540 ESPx Hardware Installation Guide
A-8
Table A-6
lists the specifications for the 32-channel with OSC terminal
mux/demux module.
If the chassis loses CPU power, traffic on the 32-channel module will be lost or
seriously degraded. The 32-channel module uses arrayed wavelength grating
(AWG) filters, which require temperature control. A power failure significantly
reduces the power at the receiver because the passband of the filter is
temperature sensitive.
Table A-6
32-Channel with OSC Terminal Mux/Demux Specifications
Description
Dimensions
Weight
Operating temperature
Storage temperature
Channel mapping
Fiber
Monitor, OSC, and common ports
Add/drop channel connectors
Tap ratio
1. See
Table A-2
for band A to H wavelengths.
Appendix A
Specification
13.8 x8.6 in. (33 x 22 cm)
3.5 lbs (1.59 kg)
32 to149°F (0~to 65°C)
-40 to 185°F (-40 to 85°C)
1
Bands A to H
SMF-28 or equivalent
Low loss tuned MU/UPC
Low loss MTP female /APC
-20 ± 1 dB (with connectors)