99/08/03
Explanation
• This operator selects the specified output tray and output mode.
• This operator is ignored when no tray is specified.
• The '1' and '2' parameters are executed for all output trays other than ones which are defined and protected
as mailboxes.
• This operator is registered in 'statusdict'.
<Example>
statusdict begin
0 setoutputmode
end
3.1.6.
Command
TrayNumber setoutputprotect
Parameter
TrayNumber
Lower unit:
Lower unit + Upper unit:
Default = 0
Explanation
• This operator sets the bins with numbers larger than the TrayNumber specified as mailbox use only. They
cannot then be used for either stacker or sorter functions.
• If the bin number is set to 0, the mailbox protection is released, then all bins can be used for stacker and
sorter functions.
• If the bin number is set out of the effective range, this operator is ignored.
MX not installed
Lower unit installed
Lower & upper unit installed
• This operator is registered in 'statusdict'.
<Example>
statusdict begin
5 setoutputprotect
end
APPENDIX E REFERENCE LIST OF MX-2000 SERIES UNIQUE COMMANDS - 8
PS mailbox protection & bin number setting
#1 to 5 from bottom to top
#1 to 10 from bottom to top
Setting type
Effective range
0
0, 1 ∼ 5
0, 1 ∼ 10

Advertisement