99/08/04
90 LPRINT "FT4,100,45;RA4250,4750;"
100 LPRINT CHR$(27); "%0A";
110 LPRINT CHR$(27); "E";
120 END
<Sample 34>
RR - Fill rectangle relative
RR X, Y[;]
X ; X coordinate of opposite corner for the rectangle
Y ; Y coordinate of opposite corner for the rectangle
• Coordinates relative to the current position in current units.
• Fill the rectangle formed by the current position and the opposite corner specified by X and Y.
• After plotting the cursor returns to its point of origin.
• Plotting is performed whether the pen is up or down.
10 ' - Fill Relative Rectangle -
20 WIDTH "LPT1:", 255
30 LPRINT CHR$(27); "E";
40 LPRINT CHR$(27); "%0B";
50 LPRINT "IN;SP1;PA5000,4000;"
60 LPRINT "FT1;RR750,750;"
70 LPRINT "PR750,0;"
80 LPRINT "FT3,100;RR750,750;"
90 LPRINT "PR0,750;"
100 LPRINT "FT2;RR750,750;"
110 LPRINT "FT4,100,45;RR-750,750;"
120 LPRINT CHR$(27); "%0A";
130 LPRINT CHR$(27); "E";
140 END
<Sample 35>
WG - Fill wedge
WG r , q1 , qc (, qd )[;]
r ; Radius in current units
q1 ; Start point angle
qc ; Arc angle
qd ; Chord angle
• Fill in a wedge centred on the current position with radius r, start point angle q1, arc angle qc and chord
angle qd.
• After plotting, the cursor returns to its point of origin.
• Plotting is performed whether the pen is up or down.
• You should use this command with the type "isotropic". Anisotropic type may make the wedge stretch.
r specifies the radius of circle. A positive value places the 0° reference point onto the positive x-axis and the
negative value places it onto the negative x-axis.
• The value for q1 is a clamped real number.
• q1 specifies the wedge starting point related to the 0° reference point.
• When q1 is positive, the positive direction of the X axis relative to the current position is set at 0 degrees and
the start point is sought in the counterclockwise direction. The opposite occurs when q1 is negative: the
negative X axis is set at 0 degrees and the start point is sought by going clockwise.
• qc specifies the angle of the wedge.
• The value for qc is a clamped real number.
• Plotting proceeds counterclockwise when qc is positive and clockwise when negative.
• The value for qd is a clamped real number.
• When qd is not specified, the chord angle is the default value ( 5 degrees ).
CHAPTER 4 HP-GL/2 - 28