Programming; Description Of Parameters - Danfoss MCO 350 Operating Instructions Manual

Syncronising controller
Table of Contents

Advertisement

Syncronising Controller MCO 350 Operating
Instructions

3. Programming

3.1. Description of Parameters

19-00 Store data
Option:
[0]
[1]
19-01 Test run; Program 1
Option:
19-01 Synchronous operation; Program 2
Option:
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
With the selections "0" - "2" and "7" the motor is always controlled keeping the actual position
when stopping synchronisation (input 1 = "0").
Function:
Here you can save the gear-ratio data permanently in the EE-
PROM
no function
Gear data is being
While saving, the value remains "1"; when saving is finished,
saved
the value automatically reverts to "0". At the same time, during
saving, Output O5 "Saving" is set to "1". Saving is not possible
during operation, but only in the stopped state.
Function:
Test run speed: Specify here the speed at which the test runs
are to be carried out. The speed is specified as a percentage of
the maximum speed defined in par. 32-80.
Function:
Type of operation: Select here the type of operation of the syn-
chronising Controller
Speed synchronising
Position synchronising
Marker synchronising
Speed synchronising with motor coast after stop
Position synchronising with motor coast after stop
Marker synchronising with motor coast after stop
.
Speed synchronising with motor coast after stop and setting of
gear ratio via analogue input 54
Speed synchronising with setting of gear ratio via analogue in-
put 54.
®
MG.33.Q1.02 - VLT
is a registered Danfoss trademark
3. Programming
3
27