Syncronising Controller MCO 350 Operating
Instructions
19-96 Track error (read only)
Option:
32-00 Incremental Signal Type (Slave)
Option:
[0]
[1]
[2]
32-01 Incremental Resolution (Slave)
Option:
32-02 Absolute Protocol (Slave)
Option:
[0]
[1]
[2]
32-03 Absolute Resolution (Slave)
Option:
32-05 Absolute Encoder Data Length (Slave)
Option:
32-06 Absolute Encoder Clock Frequency (Slave)
Option:
32-07 Absolute Encoder Clock Generation (Slave)
Option:
Function:
"Track-error": The synchronisation error is displayed with the
value calculated in par. 19-15.
Function:
None
Choose if an absolute encoder is used
RS422 (TTL/Line driv-
er)
Sinusoidal 1 Vpp
Choose if 1 V peak to peak analog incremental encoder is used.
Function:
Enter the pulses per revolution
Function:
None
choose if an incremental encoder is used.
SSI.
SSI with filter
choose if the encoder signal is unstable.
Function:
Enter the positions per revolution.
Function:
Enter the number of data bits of the connected absolute encod-
er.
Function:
Enter the clock frequency according to the encoder manufac-
turer specifications.
Function:
Off
Clock signal is not generated.
On
Clock signal is generated, this is most commonly used.
®